Skip to main content
4 events
when toggle format what by license comment
Jul 2, 2020 at 6:22 vote accept Embedded_Dude
Jul 2, 2020 at 4:18 comment added hobbs @Forat that's the closest option, it's just that there is no good option with that master clock.
Jul 2, 2020 at 3:12 comment added Embedded_Dude I am not an expert on Baud Rate calculations, tried measuring the signal with the new baud rate that you gave me, I reduced the time cursor in the oscilloscope to 1/10923 = 92us and and I got the right results. However, I don't understand why I got the wrong baud rate as I used to the recommendation from the User Guide (pg 782). for brclk = 32768 Hz, Baud Rate = 9600 and UCOS16 = 0 they recommended UCBR = 3 and UCBRS = 0x92
Jul 2, 2020 at 2:38 history answered Justme CC BY-SA 4.0