Apr 6, 2021 at 23:40 | comment | added | Edgar Brown | @TonyStewartEE75 See my own answer. The IXYS switches were the issue. Changing to the Vishay SSRs solved the problem. | |
Apr 2, 2021 at 5:42 | comment | added | D.A.S. | don’t modulate off! chose a low current such that your response will be as you expect instead Coss x N x R leakage = xxx us like <5% or so. Turn off a current sink will be a problem with this design. similar problems occur with other designs like this. | |
Feb 17, 2021 at 0:08 | vote | accept | Edgar Brown | ||
Feb 17, 2021 at 0:08 | answer | added | Edgar Brown | timeline score: 1 | |
Jan 29, 2021 at 18:09 | history | edited | Edgar Brown | CC BY-SA 4.0 |
Added explanatory note
|
S Jan 29, 2021 at 17:19 | history | mod moved comments to chat | |||
S Jan 29, 2021 at 17:19 | comment | added | Voltage Spike♦ | Comments are not for extended discussion; this conversation has been moved to chat. | |
Jan 26, 2021 at 20:51 | history | edited | Edgar Brown | CC BY-SA 4.0 |
Added a clarifying note and fixed a typo in the schematic
|
Jan 26, 2021 at 19:15 | history | asked | Edgar Brown | CC BY-SA 4.0 |