The voltage and currents on the load have to be constrained within all limits simultaneously: -
- Maximum current of 25 amps
- Maximum voltage of 750 volts
- Maximum product of voltage and current of 2400 watts (e.g. 10 amps and 240 volts)
I was thinking that it was possible to find an "SOA" of the electronic load into the datasheet, but I did not find it.
You can make an SOA curve from the above three bullet points: -