Timeline for Replacement cap (filter / choke) for oscilloscope power supply
Current License: CC BY-SA 3.0
4 events
when toggle format | what | by | license | comment | |
---|---|---|---|---|---|
Dec 31, 2013 at 11:24 | comment | added | Polynomial | Thanks for the answer. Scope is now working with the cap removed (just to hold me over for the week) for now. I have a couple of replacements coming from CPC - two identical to the failed cap, and two very similar caps that are more easily sourced. Always pays to have spares :) | |
Dec 31, 2013 at 11:18 | vote | accept | Polynomial | ||
Dec 30, 2013 at 19:11 | history | edited | zeqL | CC BY-SA 3.0 |
added 2 characters in body
|
Dec 30, 2013 at 19:02 | history | answered | zeqL | CC BY-SA 3.0 |