I am using the TPS92692 in buck-boost mode with an analog signal to set Iadj and PWM. When I start the circuit, it consistently goes into fault mode and the fault pin is periodically set low. However, after about 5 seconds, everything works fine and the fault pin is no longer set low but after some time, the current also gradually decreases. The input voltage is 24 V and the circuit powers 7 LEDs (with a forward voltage range of 2.8-3.4 V for each LED). In this case, Iadj is set to 1.46 V and the PWM is 2.44 V Here is the circuit: [![enter image description here][1]][1] Current start-up signal: [![enter image description here][2]][2] Fault pin start-up signal: [![enter image description here][3]][3] Current after about 5 s: [![enter image description here][4]][4] [1]: https://i.sstatic.net/7J3aGneK.png [2]: https://i.sstatic.net/VwHz3fth.png [3]: https://i.sstatic.net/lGZSYqj9.png [4]: https://i.sstatic.net/JpLk1fj2.png