Skip to main content
added 209 characters in body
Source Link
mitch33
  • 89
  • 1
  • 2
  • 11

I am trying to drive a "piezo atomizer" which is pretty much a transducer from what I can see.

The specs on the transducer are as follows:

-30-50VPP   

-Resonant frequency fr: 190 KHz±5KHz   

-Resonant impedance Zm: ≤250 Ω   

-static capacitance Cs: 2.2nF ±30%   

-Test Condition: 25±3 °C 40~70% R.H.   

-Cs => LCR meter at 1KHz 1Vrms

I thought I would be able to drive the transducer using the following circuit. I can get the the transducer to creak small bubbles when its in water but I can not get it to act like it should (a small humidifier).

This is what I am getting from the net that connects collector of the npn and the negative lead of the piezo. enter image description here

Any suggestions as to where I am going wrong?

schematic

simulate this circuit – Schematic created using CircuitLab

I am trying to drive a "piezo atomizer" which is pretty much a transducer from what I can see.

The specs on the transducer are as follows:

-30-50VPP  -Resonant frequency fr: 190 KHz±5KHz  -Resonant impedance Zm: ≤250 Ω  -static capacitance Cs: 2.2nF ±30%  -Test Condition: 25±3 °C 40~70% R.H.  -Cs => LCR meter at 1KHz 1Vrms

I thought I would be able to drive the transducer using the following circuit. I can get the the transducer to creak small bubbles when its in water but I can not get it to act like it should (a small humidifier).

Any suggestions as to where I am going wrong?

schematic

simulate this circuit – Schematic created using CircuitLab

I am trying to drive a "piezo atomizer" which is pretty much a transducer from what I can see.

The specs on the transducer are as follows:

-30-50VPP 

-Resonant frequency fr: 190 KHz±5KHz 

-Resonant impedance Zm: ≤250 Ω 

-static capacitance Cs: 2.2nF ±30% 

-Test Condition: 25±3 °C 40~70% R.H. 

-Cs => LCR meter at 1KHz 1Vrms

I thought I would be able to drive the transducer using the following circuit. I can get the the transducer to creak small bubbles when its in water but I can not get it to act like it should (a small humidifier).

This is what I am getting from the net that connects collector of the npn and the negative lead of the piezo. enter image description here

Any suggestions as to where I am going wrong?

schematic

simulate this circuit – Schematic created using CircuitLab

Source Link
mitch33
  • 89
  • 1
  • 2
  • 11

Driver for piezo atomizer/transducer

I am trying to drive a "piezo atomizer" which is pretty much a transducer from what I can see.

The specs on the transducer are as follows:

-30-50VPP -Resonant frequency fr: 190 KHz±5KHz -Resonant impedance Zm: ≤250 Ω -static capacitance Cs: 2.2nF ±30% -Test Condition: 25±3 °C 40~70% R.H. -Cs => LCR meter at 1KHz 1Vrms

I thought I would be able to drive the transducer using the following circuit. I can get the the transducer to creak small bubbles when its in water but I can not get it to act like it should (a small humidifier).

Any suggestions as to where I am going wrong?

schematic

simulate this circuit – Schematic created using CircuitLab