Dec 21, 2016 at 11:50 comment added Olin Lathrop @Edris: Not really. You say the max current is 10 A. If you have a 200 mV drop be full scale, then it will only dissipate 2 W. That would mean a 20 mOhm resistor. At such low resistances, make sure to use 4-wire measurement. In other words, make sure the sense wires with the 200 mV signal don't carry the 10 A current.
Dec 20, 2016 at 23:38 comment added Edris Keyam Yes I understand but this will make alot of power disipate.
Dec 20, 2016 at 22:27 history edited Olin Lathrop CC BY-SA 3.0
added 63 characters in body
Dec 20, 2016 at 19:56 history answered Olin Lathrop CC BY-SA 3.0