Jun 4, 2017 at 0:50 | comment | added | Veda Sadhak | Should have figured thats basically a short....I will try to do the differential voltage measurement aswell. | |
Jun 4, 2017 at 0:43 | comment | added | Veda Sadhak | Thanks for the info, I will keep in mind the reference of my scope connections. Also, I have posted the measurement with both gate signals measured with reference to ground, it still seems that there is a delay that happens in the fall time of the high side drive. | |
Jun 3, 2017 at 13:22 | comment | added | sstobbe | I think Andy has identified your largest issue with probing, but also watch out for the isolation bench-top power supplies, while they provide good DC isolation, the transformer winding form a big capacitor to mains ground. I would use a 9V or 12V battery for your isolated supply before eventually going to a bootstrapped supply. | |
Jun 3, 2017 at 10:06 | history | answered | Andy aka | CC BY-SA 3.0 |