Aug 8, 2018 at 6:31 vote accept pxidr
Feb 20, 2018 at 22:30 history edited user105652 CC BY-SA 3.0
Moved italics to include entire sentence.
Feb 20, 2018 at 21:13 comment added user105652 @JonRB. Not as much as you think, especially 40 mm MOV's at 150% rating. In running a UL testing lab at my last job, UL was concerned with durability and de-rating by constant usage as well. 5,000 hits at 10 kA was the basic test they had to pass. Likely the OP's VFD has snubbers to protect the output stage.
Feb 20, 2018 at 21:06 comment added user16222 except MOV's deteriorate with each usage
Feb 20, 2018 at 20:59 history answered user105652 CC BY-SA 3.0