Mar 15, 2018 at 5:16 comment added Solar Mike Each loop of one coil...
Mar 14, 2018 at 23:20 comment added plonker I do not understand, The field coils are connected to each other at one end, there are four coils in the motor, and three of them are connected?How can they short?
Mar 13, 2018 at 22:47 comment added Solar Mike It is also important that the field coils don't short between each other as well....
Mar 13, 2018 at 21:29 comment added plonker Thank you for that, as it is important that the field coils do not short out on the outer casing I would have thought that insulation tape would have been a better bet, in my case rust inside the case has decayed the cotton tape quite badly, hence the short, surprised that the magnetic field in not affected with rubber tape, Live and learn!
Mar 12, 2018 at 15:27 history answered Solar Mike CC BY-SA 3.0