Jul 28, 2018 at 7:29 | comment | added | Transistor | Yup. Speed reading late at night is risky. Thank you. How did you calculate 1000 - 2000 W per phase? | |
Jul 28, 2018 at 7:26 | history | edited | Transistor | CC BY-SA 4.0 |
Fixed errors.
|
Jul 28, 2018 at 5:08 | comment | added | K H | He's using 1 800VA transformer per phase and you changed a 267 into a 167. At any rate, he's got 800VA per phase at 600V, so he wants to be able to test [email protected] RMS per phase. That gives 450 ohms per phase and a power rating of ~1000-2000 W per phase. | |
Jul 27, 2018 at 17:27 | history | answered | Transistor | CC BY-SA 4.0 |