Timeline for Trouble with instrumentation and simulation of the common-mode response of a filter
Current License: CC BY-SA 4.0
6 events
when toggle format | what | by | license | comment | |
---|---|---|---|---|---|
Dec 21, 2018 at 7:41 | comment | added | Warren Hill | I can't see "K1 L1 L2 1" on your circuit but that's the idea try "K1 L1 L2 0.998" as the windings will not couple perfectly and there will be some leakage inductance. | |
Dec 20, 2018 at 16:27 | comment | added | pnatk | Are my parameters wrong on my circuit like K1 L1 L2 1 ? | |
Dec 20, 2018 at 15:26 | comment | added | Warren Hill | L1 and L2 are coupled inductors as are L3 and L4 so at a minimum you will need to add two K lines (coupling coefficients) | |
Dec 20, 2018 at 15:17 | answer | added | Andy aka | timeline score: 1 | |
Dec 20, 2018 at 13:44 | history | edited | pnatk | CC BY-SA 4.0 |
edited title
|