Timeline for Proper inrush current limiter 50A universal motor
Current License: CC BY-SA 4.0
10 events
when toggle format | what | by | license | comment | |
---|---|---|---|---|---|
Jan 16, 2020 at 21:08 | comment | added | Soheil Paper | @Phil_G i updated the motor link | |
Jan 16, 2020 at 21:04 | history | edited | Soheil Paper | CC BY-SA 4.0 |
deleted 152 characters in body
|
Jan 16, 2020 at 20:37 | comment | added | D.A.S. | @PhilG it uses same motor but poor failure analysis and no good solution given yet same problem with 25A switch !! Why? because arc burns out contacts on open ,.. not surge start | |
Jan 16, 2020 at 20:36 | comment | added | Phil G | Your link is for a relay, not the motor. Having found it at aliexpress.com/i/32960700752.html there's no way that's a 2000W motor, so its running current is likely far less than you think, but your issue is with the inrush. | |
Jan 16, 2020 at 20:16 | answer | added | D.A.S. | timeline score: 2 | |
Jan 16, 2020 at 19:48 | comment | added | winny | Looks like your universal motor is living a hard life: electronics.stackexchange.com/questions/473290/… | |
Jan 16, 2020 at 19:24 | comment | added | D.A.S. | 5 € too expensive for Dentists ?? . Why using such a cheap vacuum motor? Poor design quality | |
Jan 16, 2020 at 19:07 | history | edited | Soheil Paper | CC BY-SA 4.0 |
added 94 characters in body; added 9 characters in body; added 235 characters in body
|
Jan 16, 2020 at 19:05 | comment | added | D.A.S. | Switch must be rated for 300% of Motor rating or derated to 33% | |
Jan 16, 2020 at 19:02 | history | asked | Soheil Paper | CC BY-SA 4.0 |