Jun 18, 2020 at 23:20 comment added DKNguyen Use static (safer than global) variables as persistent flags if you can write it all in a self-contained function.
Jun 18, 2020 at 21:52 answer added Justme timeline score: 0
Jun 18, 2020 at 21:11 comment added Turbo J Ever heared of global variables (and volatile)..?
Jun 18, 2020 at 20:57 comment added Chris Stratton It's a little unclear what you are trying to do, but likely you want user input to set some configuration information in a volatile flag somewhere, and then have the ISR look at that and to know which LED to blink. Probably always turn the unrequested ones off as the change in request may not be synchronous with the state of the LED.