Jan 26, 2021 at 6:22 comment added JenilDave @Neil_UK Thanks and I will make sure that I add advantages and disadvantages in future posts. Thanks for your guidance EE.SE Community!
Jan 25, 2021 at 14:13 comment added Neil_UK @JenilDave Your drawing is fine, it's completely legible. However, please add some text to your answer saying something along the lines of 'don't do this because ...' if you are going to leave it up.
Jan 25, 2021 at 11:59 comment added Dilshod I knew that having different sizes of batteries in series wouldn't work at a full capacity. Whatever the size of the smallest battery, that would be then your capacity. I am also new into the electric works. Don't worry about the drawing. As long as the reader can understand it. Welcome!
Jan 25, 2021 at 11:15 comment added JenilDave @Neil_UK I'm sorry I didn't have intension to damage the questioner's equipment. Infact this field is very new to me and what I had learnt until now I thought would help the questioner. If this post is very much harmful then please tell I won't post any answers without any detailed knowledge about that and please consider to flag this question or ping me to delete it or down vote such that others should not repeat mistake made by me and simply ignore my answer.
Jan 25, 2021 at 8:47 comment added Neil_UK While I echo KH's welcome, I would say very strongly do not post answers that will damage the OP's equipment without at least mentioning that fact in your answer. Series connection of unequal capacity risks over-discharge on the single cells if voltage monitoring is done on the whole string. The schematic editor button is right there on the editor toolbar, though it's easy to miss. It's next to the image add button.
Jan 25, 2021 at 8:39 comment added JenilDave Thanks for your welcoming gesture ! @KH
Jan 25, 2021 at 8:30 comment added K H PS Welcome to EE.SE =)
Jan 25, 2021 at 8:26 comment added JenilDave Thanks for the suggestion, I agree on your point.
Jan 25, 2021 at 8:25 history rollback JenilDave
Rollback to Revision 1
Jan 25, 2021 at 8:25 comment added K H Putting sets of cells with different total capacity in series like this is a bad idea. There is no way to charge such an arrangement properly, and no way to safely discharge its full capacity. As far as the diagram, When you're authoring a question, one of the buttons at the top will bring up a schematic editor and it's rather easy to find most components in it, although hand drawings aren't completely forbidden.
S Jan 25, 2021 at 8:24 history suggested Bahtiyar Bayram CC BY-SA 4.0
added circuit
Jan 25, 2021 at 8:21 review Suggested edits
S Jan 25, 2021 at 8:24
Jan 25, 2021 at 8:02 history answered JenilDave CC BY-SA 4.0