Skip to main content
8 events
when toggle format what by license comment
Mar 30, 2021 at 10:31 comment added Jasen Слава Україні by regulation, I meant laws and other legal requirements.
Mar 28, 2021 at 6:22 comment added Stackexchange Thank you but i dont understand what u meant in the last paragraph( 16.5w but ..... power factor regulation???)
Mar 27, 2021 at 8:12 comment added winny The 0.5 A has very little to do with reality. When you go for CE, UL or similar certification, the certified body tests that you are below the rating. For all products I’ve designed and put forward for approval, it’s maximum continuous power consumption divided by minimum input voltage, plus margin and round up that number and you get a pass.
S Mar 27, 2021 at 6:35 history suggested Lars Hankeln CC BY-SA 4.0
Umlauts and some minor stuff
Mar 27, 2021 at 6:31 review Suggested edits
S Mar 27, 2021 at 6:35
Mar 27, 2021 at 5:59 history edited Jasen Слава Україні CC BY-SA 4.0
added 98 characters in body
Mar 27, 2021 at 5:51 history edited Jasen Слава Україні CC BY-SA 4.0
added 229 characters in body
Mar 27, 2021 at 5:43 history answered Jasen Слава Україні CC BY-SA 4.0