Timeline for ESP32 driving Solenoid requiring 2A/24V DC with IRF520?
Current License: CC BY-SA 4.0
7 events
when toggle format | what | by | license | comment | |
---|---|---|---|---|---|
May 6, 2021 at 18:06 | comment | added | Yordan Yanakiev | I've moved the topic here, after the practitioners in the discussion pointed me more toward the right question: electronics.stackexchange.com/questions/563848/… | |
May 6, 2021 at 18:05 | vote | accept | Yordan Yanakiev | ||
May 6, 2021 at 17:32 | answer | added | zozwold | timeline score: 2 | |
May 6, 2021 at 15:44 | comment | added | Yordan Yanakiev | Nope, no PWM. Just simple switching on/off the solenoid. | |
May 6, 2021 at 15:41 | comment | added | gcr | Is the application using the IRF520 FET as a simple on/off switch, or do you need to PWM control it? And if you need PWM at what frequency? If it's just an on/off you could use a smaller logic level controllable FET to control the gate voltage of the IRF520. Perhaps with a resistor divider on your 24V rail to maintain Vgs < 20V. | |
May 6, 2021 at 15:32 | history | edited | Yordan Yanakiev | CC BY-SA 4.0 |
deleted 2 characters in body
|
May 6, 2021 at 15:26 | history | asked | Yordan Yanakiev | CC BY-SA 4.0 |