Jul 13, 2022 at 3:17 comment added ASG Thanks. We were considering a capacitor type design just prior to the ADC. The sensors are 120 Ohm strain gages, so it would have worked quite well, so long as the capacitor was selected to match the resistance. However, I plan to go with the suggestion of using a simultaneous sampling ADC. The answer was literally using the keywords in my question. Oh! Well! Feeling like a chump now!
Jul 12, 2022 at 3:42 history answered PStechPaul CC BY-SA 4.0