Dec 19, 2022 at 22:13 comment added Tim Williams @Kubahasn'tforgottenMonica Yes, good point: to be precise, R3 needs to be common to R1's reference terminal on that side.
Dec 19, 2022 at 20:28 comment added Kuba hasn't forgotten Monica That's the approach I'd recommend. It's cheap and performs quite well. The mosfets have enough gate-drain capacitance to stabilize the op-amp, usually. The connections to R1 should still be Kelvin of course! Nothing can work around that.
Dec 19, 2022 at 15:24 history answered Tim Williams CC BY-SA 4.0