Dec 5, 2023 at 20:26 | comment | added | user120632 | Thank you for all the help! | |
Dec 5, 2023 at 20:25 | vote | accept | user120632 | ||
Dec 4, 2023 at 21:10 | comment | added | Spehro 'speff' Pefhany | Vgt specifies the maximum gate voltage when a trigger current is applied to the gate. In the datasheet I linked it's 1.3V (max) in all 3 specified quadrants. When the triac is conducting, a bit of voltage comes out of the gate. This is not well specified, but it will be similar (and of course it will be less than, and the same polarity as, the 'A2' voltage with respect to 'A1') and there will be some internal series resistance (again, not well specified). | |
Dec 4, 2023 at 17:50 | comment | added | user120632 | Thanks for the answer! Is there a datasheet parameter that specifies the gate voltage when current is flowing, or should I just assume it to be around 1V for all triacs? | |
Dec 2, 2023 at 15:42 | history | answered | Spehro 'speff' Pefhany | CC BY-SA 4.0 |