Apr 4, 2021 at 16:01 comment added Verbal Kint Finally, when you graph magnitude and phase responses, I've found that having symmetrical scale ends makes it easier to read and interpret (+/- 50 dB and +/- 180° for instance). If you plot the phase and the magnitude on the same chart, then having them share a common 0 reference makes phase and gain margins easier to extract in my opinion.
Apr 4, 2021 at 15:58 comment added Verbal Kint You are plotting the open-loop gain of a converter operated in closed-loop conditions. Regarding SIMPLIS, I would not place the stimulus source where you installed it. Please try inserting it in series above \$R_4\$ as I did in the platforms that I described there. Also, are you sure a 5-V bias is enough to properly drive the IRF530 MOSFET? I always prefer to start with controlled switches, check that it works, then complicate later on.
Apr 4, 2021 at 15:40 history asked Linda Yu CC BY-SA 4.0