1
\$\begingroup\$

It is a common practice for capacitor manufactures to define either the ESR or the dissipation factor (aka loss angle) at a given frequency (e.g. 120Hz, 1kHz or 1MHz). It is also clear that their dependence on the frequency is not linear. The question is, is it possible anyhow to use some sort of interpolation to have a first-order approximation of the ESR at a frequency other than the one stated in the datasheet?

Thank you.

\$\endgroup\$

1 Answer 1

2
\$\begingroup\$

An interpolation (or worse an extrapolation) is only as good as the data points you have, and your reasonable expectation about the order of the function between (or worse outside) those points.

If you don't know the function, there's little point doing an interpolation.

If you have one point from the datasheet, then a zeroth order (same constant value) is a reasonable guess until you've measured the ESR at several frequencies to characterise the function.

If you have two points, then many people would be happy with a straight line drawn between the two. However, some might prefer a straight line against log frequency, and the more cautious would worry about whether there was a resonance or knee somewhere between them. Until you've measured the ESR at several frequencies to characterise the function, you won't know.

\$\endgroup\$

Your Answer

By clicking “Post Your Answer”, you agree to our terms of service and acknowledge you have read our privacy policy.

Not the answer you're looking for? Browse other questions tagged or ask your own question.