Why in the SS relay the connection line 1 and 2 appear a altern symbol, can I use to connect a DC line ?
The symbol above 24~380VAC is a capacitor ?
Why in the SS relay the connection line 1 and 2 appear a altern symbol, can I use to connect a DC line ?
The symbol above 24~380VAC is a capacitor ?
The '~' (tilde) symbol tells you that it is for AC. Internally it is using a triac and these are only suitable for AC switching.
The -| |-
symbol represents a normally open contact and is common on North American electrical schematics.
The 24-380VAC text indicates that it is rated for switching voltages in that range (which excludes DC).
Counterfeit Fotek SSRs
It appears that you are considering Fotek SSRs. Read this first: UL warns of solid state relay with counterfeit UL Recognition Mark (Release 13PN-52).
See also Big Clive's Teardown of an eBay 25A Solid State Relay (SSR).